Power Source Mode does not Change to ON (ACC) [06/2018 - ]: Procedure
- CHECK FOR DTC
- Using the Techstream, check for certification ECU (smart key ECU assembly) DTCs.
Body Electrical > Power Source Control > Trouble Codes
Body Electrical > Smart Access > Trouble Codes
Body Electrical > Starting Control > Trouble Codes
Result
Result Proceed to DTCs are not output A Smart access system with push-button start (for Start Function, Gasoline Model) DTCs are output B
Result:
B
GO TO DIAGNOSTIC TROUBLE CODE CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [06/2018 - 10/2019] , or refer to DIAGNOSTIC TROUBLE CODE CHART [10/2019 - 08/2020] , or refer to DIAGNOSTIC TROUBLE CODE CHART [08/2020 - 09/2022] , or refer to DIAGNOSTIC TROUBLE CODE CHART [09/2022 - ]
Result:
A
See step 2
- Using the Techstream, check for certification ECU (smart key ECU assembly) DTCs.
- CHECK CERTIFICATION ECU (SMART KEY ECU ASSEMBLY)
- Connect the G47 certification ECU (smart key ECU assembly) connector.
*a Component with harness connected
(Certification ECU (Smart Key ECU Assembly)) - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition G47-16 (ACCD) - Body ground Engine switch on (ACC) → Engine switch on (IG) 1 V or less → 9 V or higher Result
Proceed to OK NG
Result:
NG
REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY). Refer to REMOVAL [06/2018 - 08/2021] , or refer to REMOVAL [08/2021 - 09/2022] , or refer to REMOVAL [09/2022 - ]
Result:
OK
See step 3
- Connect the G47 certification ECU (smart key ECU assembly) connector.
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY, BATTERY AND BODY GROUND)
- Disconnect the G47 certification ECU (smart key ECU assembly) connector.
- Disconnect the 3A, 3D and 3K instrument panel junction block assembly connectors.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G47-16 (ACCD) - 3A-30 Always Below 1 Ω 3D-3 - Body ground Always Below 1 Ω G47-16 (ACCD) or 3A-30 - Other terminals and body ground Always 10 kΩ or higher - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition 3K-1 - Body ground Always 11 to 14 V Result
Proceed to OK NG
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 4
- CHECK INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (ACC RELAY)
- Remove the instrument panel junction block assembly.
Refer to REMOVAL [06/2018 - 08/2021] , or refer to REMOVAL [08/2021 - 09/2022] , or refer to REMOVAL [09/2022 - ]
- Connect all of the instrument panel junction block assembly connectors.
- Measure the voltage according to the value(s) in the table below.
*a Component with harness connected
(Instrument Panel Junction Block Assembly)- - Standard Voltage
Tester Connection Condition Specified Condition 3H-26 - Body ground Engine switch on (IG) 11 to 14 V Result
Proceed to OK NG
Result:
OK
USE SIMULATION METHOD TO CHECK. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2018 - ]
Result:
NG
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY. Refer to REMOVAL [06/2018 - 08/2021] , or refer to REMOVAL [08/2021 - 09/2022] , or refer to REMOVAL [09/2022 - ]
- Remove the instrument panel junction block assembly.