Customize Parameters [05/2019 - ]
- CUSTOMIZE PRE-COLLISION SYSTEM NOTE:
- When the customer requests a change in a function, first make sure that the function can be customized.
- Make a note of the current settings before customizing.
- Customizing with the multi-information display
HINT:
The following PCS functions and the pre-collision system sensitivity setting can be changed from their default setting.
- Turn the power switch on (IG).
- Change pre-collision system settings by operating steering pad switch.SETTINGS
Customize Setting Description Default Setting PCS Function that turns the pre-collision system on or off On On or Off Sensitivity Function that selects the warning sensitivity of the pre-collision function Middle Early, Middle or Late
- Customizing with the Techstream
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Customize Setting / Others.
- Select the setting by referring to the table below.
Others
Tester Display Description Default Setting ECU PCS Function ON/OFF State Stored Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 1 Refer to the table below Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 2 Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera PCS Warning Timing State Stored 3 Refer to the table below Not Stored $00:Not Stored,$01:Stored Forward recognition camera MEASUREMENT ITEMCustomize Setting Description Setting PCS Function ON/OFF State Stored Function to maintain the pre-collision system on/off setting when the power switch is turned on (IG) from off with the pre-collision function off. Not stored: Pre-collision system always turns on
Stored: Pre-collision system maintains offPCS Warning Timing State Stored 1 Function to set whether or not to store the warning sensitivity setting when the PCS function is on and the power switch is turned from off to on (IG). Not stored: Sensitivity and CAUTION is reset to default setting
Stored: Sensitivity and CAUTION settings are maintained as previous valuePCS Warning Timing State Stored 2 Function to set whether or not to store the warning sensitivity setting when the PCS function is off and the power switch is turned from off to on (IG). Not stored: Sensitivity and CAUTION is reset to default setting
Stored: Sensitivity and CAUTION settings are maintained as previous valuePCS Warning Timing State Stored 3 Function to set whether or not to store the warning sensitivity setting when the PCS function is turned from off to on while the power switch is turned on (IG). Not stored: Sensitivity and CAUTION is reset to default setting
Stored: Sensitivity and CAUTION settings are maintained as previous value