Hazard Warning Switch Circuit [10/2015 - 08/2019]: Procedure
- READ VALUE USING TECHSTREAM
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Body Electrical / Combination Meter / Data List.
- Read the Data List according to the display on the Techstream.
Body Electrical > Combination Meter > Data List
Tester Display Measurement Item Range Normal Condition Diagnostic Note Hazard Flasher Switch Radio receiver assembly (hazard warning signal switch) signal ON or OFF ON: Radio receiver assembly (hazard warning signal switch) on
OFF: Radio receiver assembly (hazard warning signal switch) off- Body Electrical > Combination Meter > Data List
Tester Display Hazard Flasher Switch OK
Normal conditions listed above are displayed.
Result
Proceed to OK NG
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [10/2015 - 12/2017] , or refer to PROBLEM SYMPTOMS TABLE [12/2017 - 03/2018] , or refer to PROBLEM SYMPTOMS TABLE [03/2018 - 08/2019]
Result:
NG
See step 2
- INSPECT RADIO RECEIVER ASSEMBLY (HAZARD WARNING SIGNAL SWITCH)
- Remove the radio receiver assembly (hazard warning signal switch).
Refer to REMOVAL [10/2015 - 08/2016] , or refer to REMOVAL [08/2016 - 12/2017] , or refer to REMOVAL [12/2017 - 08/2019]
- Inspect the radio receiver assembly (hazard warning signal switch).
Refer to INSPECTION [10/2015 - 08/2019]
Result
Proceed to OK NG
Result:
NG
REPLACE RADIO RECEIVER ASSEMBLY (HAZARD WARNING SIGNAL SWITCH). Refer to REMOVAL [10/2015 - 08/2016] , or refer to REMOVAL [08/2016 - 12/2017] , or refer to REMOVAL [12/2017 - 08/2019]
Result:
OK
See step 3
- Remove the radio receiver assembly (hazard warning signal switch).
- CHECK HARNESS AND CONNECTOR (RADIO RECEIVER ASSEMBLY (HAZARD WARNING SIGNAL SWITCH) - COMBINATION METER ASSEMBLY OR BODY GROUND)
- Disconnect the J11 combination meter assembly connector.
- Measure the resistance according to the value (s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition J54-9 (HAZ) - J11-2 (HZSW) Always Below 1 Ω J54-9 (HAZ) or J11-2 (HZSW) - Body ground Always 10 kΩ or higher J50-12 (GND1) - Body ground Always Below 1 Ω Result
Proceed to OK NG
Result:
OK
REPLACE COMBINATION METER ASSEMBLY. Refer to REMOVAL [10/2015 - 08/2016] , or refer to REMOVAL [08/2016 - 03/2018] , or refer to REMOVAL [03/2018 - 08/2019]
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR