Open In Bus 2 Main Bus Line [09/2015 - ]: Description
There may be an open circuit in one of the bus 2 main lines and/or a central gateway ECU CAN branch wire when the resistance between terminals 18 (CA4H) and 17 (CA4L) of the central gateway ECU is 70 Ω or higher
| Detection Item | Trouble Area |
|---|---|
| Resistance between terminals 18 (CA4H) and 17 (CA4L) of central gateway ECU is 70 Ω or higher. |
|
This malfunction is not related to the lines of a bus 2 branch except the central gateway ECU CAN branch wires or to ECUs or sensors connected a bus 2 branch.