Switch Operation of Remote Touch not Accepted [04/2013 - 09/2020]: Procedure
- START DIAGNOSTIC MODE
- Activate diagnostic mode and check if the "Service Menu" screen can be displayed.
Refer to DTC CHECK / CLEAR [04/2013 - 06/2014] , or refer to DTC CHECK / CLEAR [06/2014 - 09/2018] , or refer to DTC CHECK / CLEAR [09/2018 - 09/2020]
OK
Diagnostic mode can be activated.
Result
Proceed to OK NG
Result:
NG
See step 3
Result:
OK
See step 2
- Activate diagnostic mode and check if the "Service Menu" screen can be displayed.
- CHECK PANEL SWITCH (OPERATION CHECK)
- Enter the "Panel&Steering Switch Check Mode" screen. Refer to Check Panel & Steering Switch in Operation Check.
Refer to OPERATION CHECK [04/2013 - 09/2020]
- Operate the abnormal switch and check if the switch status is correctly displayed.
OK
The switch status is correctly displayed as operated.
Result
Proceed to OK NG
Result:
OK
REPLACE RADIO RECEIVER ASSEMBLY. Refer to REMOVAL [04/2013 - 09/2020]
Result:
NG
See step 3
- Enter the "Panel&Steering Switch Check Mode" screen. Refer to Check Panel & Steering Switch in Operation Check.
- REMOTE TOUCH SELF CHECK (SWITCH OPERATION CHECK)
- Activate self check mode.
Refer to OPERATION CHECK [04/2013 - 09/2020]
- Check switch operation.
*a Switch Illumination *b Switch Knob - Move the remote touch switch knob to the lower left.
- Check that the "HOME" and "MENU" switches illuminate when each switch on the remote touch is pressed.
Result
Result Proceed to Self check mode cannot be activated. A Some switches do not turn on the "HOME" and "MENU" switch illumination when they are pressed. All switches turn on the "HOME" and "MENU" switch illumination when they are pressed. B
Result:
B
REPLACE RADIO RECEIVER ASSEMBLY. Refer to REMOVAL [04/2013 - 09/2020]
Result:
A
See step 4
- Activate self check mode.
- REPLACE REMOTE OPERATION SWITCH
- Replace the remote operation switch.
Refer to DISASSEMBLY [04/2013 - 10/2016] , or refer to DISASSEMBLY [10/2016 - 09/2020]
- Check that each switch operation on the remote touch is accepted normally.
OK
Each switch operation is accepted normally.
Result
Proceed to OK NG
Result:
OK
END
Result:
NG
REPLACE REMOTE OPERATION BOARD. Refer to DISASSEMBLY [04/2013 - 10/2016] , or refer to DISASSEMBLY [10/2016 - 09/2020]
- Replace the remote operation switch.