Inspection [04/2013 - 09/2020]: Procedure
- INSTALL ABSORBER CONTROL ACTUATOR
- Measure the resistance according to the value(s) in the table below.
*A for LH *B for RH *a Component without harness connected
(Absorber Control Actuator)Standard Resistance
FOR LHTester Connection Condition Specified Condition 1 (FBL+) - 3 (E FL) Always 12.0 to 12.8 Ω 2 (FAL+) - 3 (E FL) Always 12.0 to 12.8 Ω 4 (FBL-) - 3 (E FL) Always 12.0 to 12.8 Ω 5 (FAL-) - 3 (E FL) Always 12.0 to 12.8 Ω FOR RHTester Connection Condition Specified Condition 1 (FBR+) - 3 (E FR) Always 12.0 to 12.8 Ω 2 (FAR+) - 3 (E FR) Always 12.0 to 12.8 Ω 4 (FBR-) - 3 (E FR) Always 12.0 to 12.8 Ω 5 (FAR-) - 3 (E FR) Always 12.0 to 12.8 Ω - Check absorber control actuator operation.
Refer to OPERATION CHECK [04/2013 - 09/2020]
- Measure the resistance according to the value(s) in the table below.