LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2017 >> IS 200t Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> Testing & Diagnosis >> Engine Control System (8AR-FTS) - Diagnostic Codes (10 Of 14) >> SFI System >> DTC P062F-44: Internal Control Module EEPROM Data Memory Failure [09/2019 - 09/2022] >> Typical Malfunction Thresholds

Typical Malfunction Thresholds

CASE 1

The following conditions is met 2 data or more
One of the following conditions (a), (b) or (c) is met More than 3 times
(a) EEPROM communication timeout Occurred
(b) Permanent Fault Code Not stored
(c) Permanent Fault Code Not equal to commanded Fault Code
CASE 2

The following conditions is met 2 data or more
Either of the following conditions (a) or (b) is met More than 3 times
(a) EEPROM communication timeout Occurred
(b) Permanent Fault Code Stored
CASE 3

Either of the following conditions is met 1 or 2
1. The following conditions is met 2 data or more
EEPROM access error (more than 3 times) Occurred
2. Permanent Fault Code data (more than 10 times) Mismatch