Installation [08/2015 - ]: Procedure
- INSTALL STABILIZER CONTROL ECU
- Install the stabilizer control ECU with the bolt.
Torque: 14 N*m (138 kgf*cm, 10 ft.*lbf)
NOTE:- Replace the stabilizer control ECU with a new one if it is dropped.
- Make sure the bracket rotation stopper touches the installation position.
- Connect the connector.NOTE:
Securely connect the connector.
- Install the stabilizer control ECU with the bolt.
- INSTALL LOWER NO. 1 INSTRUMENT PANEL AIRBAG ASSEMBLY
- Install the lower No. 1 instrument panel airbag assembly (Refer to INSTALLATION [08/2015 - ] ).
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL NOTE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected (Refer to INITIALIZATION [08/2015 - 08/2019] , or refer to INITIALIZATION [08/2019 - 08/2021] , or refer to INITIALIZATION [08/2021 - 08/2022] , or refer to INITIALIZATION [08/2022 - ] ).