Typical Enabling Conditions
CASE 1
| Monitor runs whenever following DTCs not present | None |
| Secondary air injection pump | Operating |
| Secondary air injection switching valve | Operating |
| Battery voltage | 8 V or higher |
| Engine switch | On (IG) |
| Starter | OFF |
CASE 2
| Monitor runs whenever following DTCs not present | None |
| Secondary air injection pump | Not operating |
| Secondary air injection switching valve | Not operating |
| Battery voltage | 8 V or higher |
| Engine switch | On (IG) |
| Starter | OFF |