Inspection [09/2014 - ]: Procedure
- INSPECT POWER SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition 5 (SS1) - 6 (AGND)
1 (SS2) - 6 (AGND)Not pushed 10 kΩ or higher Pushed Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Power Switch)If the result is not as specified, replace the power switch.
- Apply battery voltage between the terminals of the switch, and check the illumination condition of the power switch.
OK
Measurement Condition Specified Condition Battery positive (+) → Terminal 9 (SWIL)
Battery negative (-) → Terminal 6 (AGND)Illuminates HINT:
- If a positive (+) battery lead and a negative (-) battery lead are incorrectly connected, the power switch indicator light will not illuminate.
- If the voltage is too low, the indicator light will not illuminate.
If the result is not as specified, replace the power switch.
- Measure the resistance according to the value(s) in the table below.