DTC B1796: Sleep Operation Failure of Occupant Classification ECU [07/2015 - ]: Procedure
- REPLACE OCCUPANT DETECTION ECU
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Replace the occupant detection ECU. Refer to REMOVAL [07/2015 - ]
- Connect the cable to the negative (-) auxiliary battery terminal.
Result: NEXT
NEXT
See step 2
- PERFORM ZERO POINT CALIBRATION AND SENSITIVITY CHECK
- Using the Techstream, perform Zero Point Calibration and Sensitivity Check. Refer to INITIALIZATION [07/2015 - ]
Result: NEXT
NEXT
END