DTC B1796: Sleep Operation Failure of Occupant Classification ECU [08/2014 - ]: Procedure
- REPLACE OCCUPANT DETECTION ECU
- Turn the power switch off.
- Disconnect the cable from the negative (-) auxiliary battery terminal.
- Replace the occupant detection ECU (Refer to Removal [08/2014 - ] ).
Result: NEXT
NEXT
Refer to 2
- PERFORM ZERO POINT CALIBRATION
- Connect the cable to the negative (-) auxiliary battery terminal.
- Turn the power switch on (IG).
- Using the Techstream, perform Zero Point Calibration (Refer to Initialization [08/2014 - ] ).
Result: NEXT
NEXT
Refer to 3
- PERFORM SENSITIVITY CHECK
- Using the Techstream, perform Sensitivity Check (Refer to Initialization [08/2014 - ] ).
Result: NEXT
NEXT
END