Yaw Rate Sensor Communication Stop Mode [08/2014 - ]: Procedure
- CHECK CAN BUS LINE FOR DISCONNECTION (YAW RATE AND ACCELERATION SENSOR BRANCH LINE)
- Turn the power switch off.
- Disconnect the yaw rate and acceleration sensor connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Switch Condition Specified Condition H87-3 (CANH) - H87-2 (CANL) Power switch off 54 to 69 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Yaw Rate and Acceleration Sensor)
Result: NG
NG
REPAIR OR REPLACE CAN BRANCH LINE OR CONNECTOR (YAW RATE AND ACCELERATION SENSOR)
Result: OK
OK
See step 2
- CHECK HARNESS AND CONNECTOR (POWER SOURCE TERMINAL)
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition H87-4 (IG) - Body ground Power switch on (IG) 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Yaw Rate and Acceleration Sensor)
Result: NG
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (POWER SOURCE CIRCUIT)
Result: OK
OK
See step 3
- Measure the voltage according to the value(s) in the table below.
- CHECK HARNESS AND CONNECTOR (GROUND TERMINAL)
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition H87-1 (GND) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Yaw Rate and Acceleration Sensor)
Result: OK
OK
REPLACE YAW RATE AND ACCELERATION SENSOR
(See article. Refer to REMOVAL [08/2014 - ] )
Result: NG
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (GROUND CIRCUIT)
- Measure the resistance according to the value(s) in the table below.