LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2015 >> GX 460 Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System (Diagnostic Codes (P062F-P2119)) >> SFI System >> DTC P144C: Open in Secondary Air Injection System Heater Control Circuit; DTC P144D: Short in Secondary Air Injection System Heater Control Circuit [08/2013 - ] >> Procedure

DTC P144C: Open in Secondary Air Injection System Heater Control Circuit; DTC P144D: Short in Secondary Air Injection System Heater Control Circuit [08/2013 - ]: Procedure

  1. INSPECT AIR PUMP HEATER RELAY (AIR PMP HTR) 
    GTY303374Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Remove the air pump heater relay (AIR PMP HTR) from the engine room relay block.
    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

    NG → REPLACE AIR PUMP HEATER RELAY (AIR PMP HTR) 

    OK: Go to next step 

  2. CHECK AIR PUMP HEATER RELAY (AIR PMP HTR) (POWER SOURCE) 
    1. Remove the air pump heater relay (AIR PMP HTR) from the engine room relay block.
      GTY461372Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      2 (Air pump heater relay (AIR PMP HTR)) - Body ground Always 11 to 14 V
      5 (Air pump heater relay (AIR PMP HTR)) - Body ground
      TEXT IN ILLUSTRATION

      *1 Engine Room Relay Block
      *2 Air Pump Heater Relay (AIR PMP HTR)

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: Go to next step 

  3. CHECK HARNESS AND CONNECTOR (ECM - AIR PUMP HEATER RELAY (AIR PMP HTR)) 
    1. Remove the air pump heater relay (AIR PMP HTR) from the engine room relay block.
    2. Disconnect the C30 ECM connector.
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      1 (Air pump heater relay (AIR PMP HTR)) - C30-21 (HAI1) Always Below 1 Ω
      1 (Air pump heater relay (AIR PMP HTR)) or C30-21 (HAI1) - Body ground Always 10 kΩ or higher

    NG → REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK → REPLACE ECM