Headlight Signal Circuit [08/2013 - ]: Procedure
- CHECK HEADLIGHT CLEANER CONTROL RELAY (HDLO VOLTAGE)
- Remove the main body ECU (multiplex network body ECU) with the connector(s) still connected. Refer to REMOVAL [08/2013 - ]
.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition G46-16 (HDLO) - Body ground Headlight dimmer switch in head Below 1 V G46-16 (HDLO) - Body ground Headlight dimmer switch not in head 11 to 14 V TEXT IN ILLUSTRATION*a Component with harness connected
(Main Body ECU [Multiplex Network Body ECU])
NG → See step 2
OK → See step 3
- Remove the main body ECU (multiplex network body ECU) with the connector(s) still connected. Refer to REMOVAL [08/2013 - ]
.
- CHECK HARNESS AND CONNECTOR (MAIN BODY ECU - HEADLIGHT CLEANER CONTROL RELAY)
- Disconnect the G46 main body ECU (multiplex network body ECU) connector.
- Disconnect the A32 headlight cleaner control relay connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition G46-16 (HDLO) - A32-1 (HDLO) Always Below 1 Ω G46-16 (HDLO) or A32-1 (HDLO) - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 4
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [08/2013 - ]
- REPLACE HEADLIGHT CLEANER CONTROL RELAY. Refer to REMOVAL [08/2013 - ]