DTC P0116: Engine Coolant Temperature Circuit Range / Performance Problem: Procedure
- CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
- Read the DTC.RESULT
Result Proceed to P0116 is output A P0116 and other DTCs are output B
B → See step 4
A: Go to next step
- INSPECT WATER INLET SUB-ASSEMBLY WITH THERMOSTAT
- Remove the water inlet sub-assembly with thermostat. Refer to REMOVAL [01/2012 - ] .
- Measure the valve opening temperature of the water inlet sub-assembly with thermostat.
Standard opening temperature
80 to 84°C (176 to 183°F)
HINT:
In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.
- Reinstall the water inlet sub-assembly with thermostat. Refer to INSTALLATION [01/2012 - ] .
NG → See step 5
OK → See step 3
- REPLACE ENGINE COOLANT TEMPERATURE SENSOR. Refer to REMOVAL [01/2012 - ]
- GO TO DTC CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [01/2012 - ]
- REPLACE WATER INLET SUB-ASSEMBLY WITH THERMOSTAT. Refer to REMOVAL [01/2012 - ]