Multi-display Power Source Circuit: Procedure
- CHECK HARNESS AND CONNECTOR (ACCESSORY METER ASSEMBLY - AUXILIARY BATTERY AND BODY GROUND)
- Disconnect the accessory meter assembly connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L169-13 (GND1) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Condition Specified Condition L169-12 (+B2) - Body ground Always 11 to 14 V L169-23 (IG) - Body ground Power switch on (IG) 11 to 14 V L169-24 (ACC) - Body ground Power switch on (ACC) 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Accessory Meter Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- Disconnect the accessory meter assembly connector.
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [09/2012 - ]