Headlight Cleaner Switch Circuit: Procedure
- INSPECT HEADLIGHT CLEANER SWITCH ASSEMBLY
- Remove the headlight cleaner switch assembly. Refer to INSPECTION [06/2012 - ]
.
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Switch Condition Specified Condition 5 - 8 Headlight cleaner switch on Below 1 Ω 5 - 8 Headlight cleaner switch off 10 kΩ or higher
NG → See step 4
OK: Go to next step
- Remove the headlight cleaner switch assembly. Refer to INSPECTION [06/2012 - ]
.
- CHECK HARNESS AND CONNECTOR (HEADLIGHT CLEANER SWITCH ASSEMBLY - HEADLIGHT CLEANER CONTROL RELAY AND MAIN BODY ECU)
- Disconnect the G54 headlight cleaner switch connector.
- Disconnect the A32 headlight cleaner control relay connector.
- Remove the main body ECU. Refer to REMOVAL [06/2012 - ] .
- Measure the resistance according to the value(s) in the table below.STANDARD RESISTANCE
Tester Connection Condition Specified Condition G54-8 - A32-2 (H) Always Below 1 Ω G54-5 - A-15 (HRLY) Always Below 1 Ω G54-8 - Body ground Always 10 kΩ or higher G54-5 - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 3
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [06/2012 - ]
- REPLACE HEADLIGHT CLEANER SWITCH ASSEMBLY. Refer to REMOVAL [06/2012 - ]