Millimeter Wave Radar Sensor Power Source Circuit: Procedure
- CHECK HARNESS AND CONNECTOR (MILLIMETER WAVE RADAR SENSOR ASSEMBLY - BATTERY AND BODY GROUND)
- Disconnect the millimeter wave radar sensor assembly connector.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition B12-5 (IGB) - Body ground Engine switch on (IG) 11 to 14 V Engine switch off Below 1 V - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition B12-2 (SGND) - Body ground Always Below 1 Ω TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Millimeter Wave Radar Sensor Assembly)
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 2
- Disconnect the millimeter wave radar sensor assembly connector.
- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE [12/2011 - ]