LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2013 >> CT 200h Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostic Codes (P106A-U0293) & Circuit Tests)) >> SFI System >> DTC P2610: ECM / PCM Internal Engine Off Timer Performance >> Typical Enabling Conditions

Typical Enabling Conditions

ALL

Monitor runs whenever following DTCs are not present None
CASE 1

All of the following conditions are met -
Engine Running
Auxiliary battery voltage 8 V or higher
Power switch On (IG)
CPU clock elapsed time 10 minutes or more
CASE 2

All of the following conditions are met -
Internal engine off timer (elapsed time from engine stop) 10 minutes or more, and less than 30 minutes
Auxiliary battery voltage 8 V or higher
Power switch On (IG)
CASE 3

All of the following conditions are met -
Internal engine off timer (elapsed time from engine stop) 40 minutes or more
Auxiliary battery voltage 8 V or higher
Power switch On (IG)