Speaker Circuit: Procedure
- CONFIRM MODEL
- Choose the model to be inspected.
Result
Model Proceed to w/o Front Center Speaker A w/ Front Center Speaker B
B → See step 3
A: Go to next step
- Choose the model to be inspected.
- CHECK HARNESS AND CONNECTOR
- Disconnect the connectors from the stereo component amplifier assembly and speakers.
- Measure the resistance between the front No. 1 speaker LH and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P44-3 (WFL+) - M13-1 Always Below 1 Ω P44-8 (WFL-) - M13-2 Always Below 1 Ω - Measure the resistance between the front No. 1 speaker RH and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P44-10 (WFR+) - L1-1 Always Below 1 Ω P44-9 (WFR-) - L1-2 Always Below 1 Ω - Measure the resistance between each of the front No. 3 speakers and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P28-4 (FR+) - L2-1 (TWR+) Always Below 1 Ω P28-10 (FR-) - L2-3 (TWR-) Always Below 1 Ω P28-3 (FL+) - M4-1 (TWL+) Always Below 1 Ω P28-9 (FL-) - M4-3 (TWL-) Always Below 1 Ω - Measure the resistance between each of the front No. 2 speakers and the front No. 3 speakers to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition L2-2 (+) - L5-1 Always Below 1 Ω L2-4 (-) - L5-2 Always Below 1 Ω M4-2 (+) - M12-1 Always Below 1 Ω M4-4 (-) - M12-2 Always Below 1 Ω - Measure the resistance between each of the rear speakers and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P44-5 (RR+) - N3-1 Always Below 1 Ω P44-12 (RR-) - N3-2 Always Below 1 Ω P44-4 (RL+) - O3-1 Always Below 1 Ω P44-11 (RL-) - O3-2 Always Below 1 Ω - Measure the resistance between each of the rear No. 3 speakers and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P44-2 (MR+) - N4-1 (+) Always Below 1 Ω P44-7 (MR-) - N4-3 (-) Always Below 1 Ω P44-1 (ML+) - O4-1 (+) Always Below 1 Ω P44-6 (ML-) - O4-3 (-) Always Below 1 Ω - Measure the resistance between each of the rear No. 2 speakers and the rear No. 3 speakers to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition N4-2 (+TW) - N6-1 Always Below 1 Ω N4-4 (-TW) - N6-2 Always Below 1 Ω O4-2 (+TW) - O6-1 Always Below 1 Ω O4-4 (-TW) - O6-2 Always Below 1 Ω - Measure the resistance between the stereo component speaker and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P28-1 (WF1+) - P21-1 (WF1+) Always Below 1 Ω P28-5 (WF1-) - P21-3 (WF1-) Always Below 1 Ω P28-2 (WF2+) - P21-2 (WF2+) Always Below 1 Ω P28-6 (WF2-) - P21-4 (WF2-) Always Below 1 Ω - Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P44-10 (WFR+) - Body ground Always 10 kΩ or higher P44-9 (WFR-) - Body ground Always 10 kΩ or higher P44-3 (WFL+) - Body ground Always 10 kΩ or higher P44-8 (WFL-) - Body ground Always 10 kΩ or higher P44-2 (MR+) - Body ground Always 10 kΩ or higher P44-7 (MR-) - Body ground Always 10 kΩ or higher P44-1 (ML+) - Body ground Always 10 kΩ or higher P44-6 (ML-) - Body ground Always 10 kΩ or higher P44-5 (RR+) - Body ground Always 10 kΩ or higher P44-12 (RR-) - Body ground Always 10 kΩ or higher P44-4 (RL+) - Body ground Always 10 kΩ or higher P44-11 (RL-) - Body ground Always 10 kΩ or higher P28-4 (FR+) - Body ground Always 10 kΩ or higher P28-10 (FR-) - Body ground Always 10 kΩ or higher P28-3 (FL+) - Body ground Always 10 kΩ or higher P28-9 (FL-) - Body ground Always 10 kΩ or higher P28-1 (WF1+) - Body ground Always 10 kΩ or higher P28-5 (WF1-) - Body ground Always 10 kΩ or higher P28-2 (WF2+) - Body ground Always 10 kΩ or higher P28-6 (WF2-) - Body ground Always 10 kΩ or higher - Measure the resistance between each of the front No. 2 speakers and body ground to check for a short circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition L5-1 - Body ground Always 10 kΩ or higher L5-2 - Body ground Always 10 kΩ or higher M12-1 - Body ground Always 10 kΩ or higher M12-2 - Body ground Always 10 kΩ or higher - Measure the resistance between each of the rear No. 2 speakers and body ground to check for a short circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition N6-1 - Body ground Always 10 kΩ or higher N6-2 - Body ground Always 10 kΩ or higher O6-1 - Body ground Always 10 kΩ or higher O6-2 - Body ground Always 10 kΩ or higher - Proceed to the next step based on the inspection result.
Result
Condition Proceed to OK B NG A
B → See step 4
A → REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR
- Disconnect the connectors from the stereo component amplifier assembly and speakers.
- Measure the resistance between the front No. 1 speaker LH and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P45-3 (WFL+) - M13-1 Always Below 1 Ω P45-8 (WFL-) - M13-2 Always Below 1 Ω - Measure the resistance between the front No. 1 speaker RH and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P45-10 (WFR+) - L1-1 Always Below 1 Ω P45-9 (WFR-) - L1-2 Always Below 1 Ω - Measure the resistance between each of the front No. 3 speakers and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P28-4 (FR+) - L2-1 (TWR+) Always Below 1 Ω P28-10 (FR-) - L2-3 (TWR-) Always Below 1 Ω P28-3 (FL+) - M4-1 (TWL+) Always Below 1 Ω P28-9 (FL-) - M4-3 (TWL-) Always Below 1 Ω - Measure the resistance between each of the front No. 2 speakers and the front No. 3 speakers to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition L2-2 (+) - L5-1 Always Below 1 Ω L2-4 (-) - L5-2 Always Below 1 Ω M4-2 (+) - M12-1 Always Below 1 Ω M4-4 (-) - M12-2 Always Below 1 Ω - Measure the resistance between each of the rear No. 2 speakers and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P45-5 (RR+) - N5-1 (+) Always Below 1 Ω P45-12 (RR-) - N5-3 (-) Always Below 1 Ω P45-4 (RL+) - O5-1 (+) Always Below 1 Ω P45-11 (RL-) - O5-3 (-) Always Below 1 Ω - Measure the resistance between each of the rear speakers and the rear No. 2 speakers to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition N5-2 (+TW) - N2-1 Always Below 1 Ω N5-4 (-TW) - N2-2 Always Below 1 Ω O5-2 (+TW) - O2-1 Always Below 1 Ω O5-4 (-TW) - O2-2 Always Below 1 Ω - Measure the resistance between the stereo component speaker and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P28-1 (WF1+) - P21-3 (WF1+) Always Below 1 Ω P28-5 (WF1-) - P21-4 (WF1-) Always Below 1 Ω - Measure the resistance between each of the rear stereo component speakers and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P45-2 (SR+) - Q26-1 Always Below 1 Ω P45-7 (SR-) - Q26-2 Always Below 1 Ω P45-1 (SL+) - Q22-1 Always Below 1 Ω P45-6 (SL-) - Q22-2 Always Below 1 Ω - Measure the resistance between the front stereo component speaker and the stereo component amplifier assembly to check for an open circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P28-8 (CTR+) - K2-1 Always Below 1 Ω P28-7 (CTR-) - K2-2 Always Below 1 Ω - Measure the resistance between the stereo component amplifier assembly and body ground to check for a short circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition P45-10 (WFR+) - Body ground Always 10 kΩ or higher P45-9 (WFR-) - Body ground Always 10 kΩ or higher P45-3 (WFL+) - Body ground Always 10 kΩ or higher P45-8 (WFL-) - Body ground Always 10 kΩ or higher P45-5 (RR+) - Body ground Always 10 kΩ or higher P45-12 (RR-) - Body ground Always 10 kΩ or higher P45-4 (RL+) - Body ground Always 10 kΩ or higher P45-11 (RL-) - Body ground Always 10 kΩ or higher P45-2 (SR+) - Body ground Always 10 kΩ or higher P45-7 (SR-) - Body ground Always 10 kΩ or higher P45-1 (SL+) - Body ground Always 10 kΩ or higher P45-6 (SL-) - Body ground Always 10 kΩ or higher P28-4 (FR+) - Body ground Always 10 kΩ or higher P28-10 (FR-) - Body ground Always 10 kΩ or higher P28-3 (FL+) - Body ground Always 10 kΩ or higher P28-9 (FL-) - Body ground Always 10 kΩ or higher P28-1 (WF1+) - Body ground Always 10 kΩ or higher P28-5 (WF1-) - Body ground Always 10 kΩ or higher P28-8 (CTR+) - Body ground Always 10 kΩ or higher P28-7 (CTR-) - Body ground Always 10 kΩ or higher - Measure the resistance between each of the front No. 2 speakers and body ground to check for a short circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition L5-1 - Body ground Always 10 kΩ or higher L5-2 - Body ground Always 10 kΩ or higher M12-1 - Body ground Always 10 kΩ or higher M12-2 - Body ground Always 10 kΩ or higher - Measure the resistance between each of the rear speakers and body ground to check for a short circuit in the wire harness.
Standard Resistance
Tester Connection Condition Specified Condition N2-1 - Body ground Always 10 kΩ or higher N2-2 - Body ground Always 10 kΩ or higher O2-1 - Body ground Always 10 kΩ or higher O2-2 - Body ground Always 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT FRONT NO. 1 SPEAKER
- Resistance check
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
W/O FRONT CENTER SPEAKERTester Connection Condition Specified Condition L1-1 - L1-2 Always 3.2 to 4.8 Ω M13-1 - M13-2 Always 3.2 to 4.8 Ω W/ FRONT CENTER SPEAKERTester Connection Condition Specified Condition L1-1 - L1-2 Always 4.8 to 7.2 Ω M13-1 - M13-2 Always 4.8 to 7.2 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Front No. 1 Speaker)
- Measure the resistance according to the value(s) in the table below.
NG → See step 19
OK: Go to next step
- Resistance check
- INSPECT REAR SPEAKER
- Resistance check
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
W/O FRONT CENTER SPEAKERTester Connection Condition Specified Condition N3-1 - N3-2 Always 3.2 to 4.8 Ω O3-1 - O3-2 Always 3.2 to 4.8 Ω W/ FRONT CENTER SPEAKERTester Connection Condition Specified Condition N2-1 - N2-2 Always 5.0 to 7.0 Ω O2-1 - O2-2 Always 5.0 to 7.0 Ω TEXT IN ILLUSTRATION*A w/o Front Center Speaker *B w/ Front Center Speaker *a Component without harness connected
(Rear Speaker)
- Measure the resistance according to the value(s) in the table below.
NG → See step 20
OK: Go to next step
- Resistance check
- INSPECT STEREO COMPONENT SPEAKER
- Resistance check
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
W/O FRONT CENTER SPEAKERTester Connection Condition Specified Condition P21-1 (WF1+) - P21-3 (WF1-) Always 1.6 to 2.4 Ω P21-2 (WF2+) - P21-4 (WF2-) Always 1.6 to 2.4 Ω W/ FRONT CENTER SPEAKERTester Connection Condition Specified Condition P21-3 (WF1+) - P21-4 (WF1-) Always 6.2 to 7.8 Ω TEXT IN ILLUSTRATION*A w/o Front Center Speaker *B w/ Front Center Speaker *a Component without harness connected
(Stereo Component Speaker)
- Measure the resistance according to the value(s) in the table below.
NG → See step 21
OK: Go to next step
- Resistance check
- CONFIRM MODEL
- Choose the model to be inspected.
Result
Model Proceed to w/o Front Center Speaker A w/ Front Center Speaker B
B → See step 12
A: Go to next step
- Choose the model to be inspected.
- INSPECT FRONT NO. 2 SPEAKER
- Resistance check
NG → See step 25
OK: Go to next step
- INSPECT FRONT NO. 3 SPEAKER
- Resistance check
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L2-1 (TWR+) - L2-3 (TWR-) Always 3.2 to 4.8 Ω L2-1 (TWR+) - L2-2 (+) Always 10 kΩ or higher L2-3 (TWR-) - L2-4 (-) Always Below 1 Ω M4-1 (TWL+) - M4-3 (TWL-) Always 3.2 to 4.8 Ω M4-1 (TWL+) - M4-2 (+) Always 10 kΩ or higher M4-3 (TWL-) - M4-4 (-) Always Below 1 Ω TEXT IN ILLUSTRATION*A for RH *B for LH *a Component without harness connected
(Front No. 3 Speaker)
- Measure the resistance according to the value(s) in the table below.
NG → See step 26
OK: Go to next step
- Resistance check
- INSPECT REAR NO. 2 SPEAKER
- Resistance check
NG → See step 27
OK: Go to next step
- INSPECT REAR NO. 3 SPEAKER
- Resistance check
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N4-1 (+) - N4-3 (-) Always 3.2 to 4.8 Ω N4-1 (+) - N4-2 (+TW) Always 10 kΩ or higher N4-3 (-) - N4-4 (-TW) Always Below 1 Ω O4-1 (+) - O4-3 (-) Always 3.2 to 4.8 Ω O4-1 (+) - O4-2 (+TW) Always 10 kΩ or higher O4-3 (-) - O4-4 (-TW) Always Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Rear No. 3 Speaker)
- Measure the resistance according to the value(s) in the table below.
NG → See step 28
OK → See step 22
- Resistance check
- INSPECT FRONT NO. 2 SPEAKER
- Resistance check
NG → See step 25
OK: Go to next step
- REPLACE FRONT NO. 2 SPEAKER
- Check that the malfunction disappears when a known good speaker is installed. Refer to REMOVAL
.
OK
Malfunction disappears.
HINT:
- Connect all the connectors to the front No. 2 speakers that were disconnected.
- When there is a possibility that either the right or left front speaker is defective, inspect by interchanging the right one with the left one.
- Perform the above inspection on both LH and RH sides.
NG → See step 14
OK → END (FRONT NO. 2 SPEAKER WAS DEFECTIVE)
- Check that the malfunction disappears when a known good speaker is installed. Refer to REMOVAL
.
- INSPECT FRONT NO. 3 SPEAKER
- Resistance check
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition L2-1 (TWR+) - L2-3 (TWR-) Always 4.8 to 6.4 Ω L2-1 (TWR+) - L2-2 (+) Always Below 1 Ω L2-3 (TWR-) - L2-4 (-) Always Below 1 Ω M4-1 (TWL+) - M4-3 (TWL-) Always 4.8 to 6.4 Ω M4-1 (TWL+) - M4-2 (+) Always Below 1 Ω M4-3 (TWL-) - M4-4 (-) Always Below 1 Ω TEXT IN ILLUSTRATION*A for RH *B for LH *a Component without harness connected
(Front No. 3 Speaker)
- Measure the resistance according to the value(s) in the table below.
NG → See step 26
OK: Go to next step
- Resistance check
- INSPECT REAR NO. 2 SPEAKER
- Resistance check
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition N5-1 (+) - N5-3 (-) Always 10 kΩ or higher N5-1 (+) - N5-2 (+TW) Always Below 1 Ω N5-3 (-) - N5-4 (-TW) Always Below 1 Ω O5-1 (+) - O5-3 (-) Always 10 kΩ or higher O5-1 (+) - O5-2 (+TW) Always Below 1 Ω O5-3 (-) - O5-4 (-TW) Always Below 1 Ω TEXT IN ILLUSTRATION*a Component without harness connected
(Rear No. 2 Speaker)
- Measure the resistance according to the value(s) in the table below.
NG → See step 27
OK: Go to next step
- Resistance check
- REPLACE REAR NO. 2 SPEAKER
- Check that the malfunction disappears when a known good speaker is installed. Refer to REMOVAL
.
OK
Malfunction disappears.
HINT:
- Connect all the connectors to the rear No. 2 speakers that were disconnected.
- When there is a possibility that either the right or left rear speaker is defective, inspect by interchanging the right one with the left one.
- Perform the above inspection on both LH and RH sides.
NG → See step 17
OK → END (REAR NO. 2 SPEAKER WAS DEFECTIVE)
- Check that the malfunction disappears when a known good speaker is installed. Refer to REMOVAL
.
- INSPECT REAR STEREO COMPONENT SPEAKER
- Resistance check
NG → See step 23
OK: Go to next step
- INSPECT FRONT STEREO COMPONENT SPEAKER
- Resistance check
NG → See step 24
OK → See step 22
- REPLACE FRONT NO. 1 SPEAKER. Refer to REMOVAL
- REPLACE REAR SPEAKER. Refer to REMOVAL
- REPLACE STEREO COMPONENT SPEAKER. Refer to REMOVAL
- PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to PROBLEM SYMPTOMS TABLE
- REPLACE REAR STEREO COMPONENT SPEAKER. Refer to REMOVAL
- REPLACE FRONT STEREO COMPONENT SPEAKER. Refer to REMOVAL
- REPLACE FRONT NO. 2 SPEAKER. Refer to REMOVAL
- REPLACE FRONT NO. 3 SPEAKER. Refer to REMOVAL
- REPLACE REAR NO. 2 SPEAKER. Refer to REMOVAL
- REPLACE REAR NO. 3 SPEAKER. Refer to REMOVAL