Translate ECU Communication Stop Mode: Procedure
- CHECK WIRE HARNESS (TRANSLATE ECU - BATTERY AND BODY GROUND)
- Disconnect the T28 translate ECU connector.
- Measure the resistance of the wire harness side connector.
Standard resistance
Tester Connection Condition Specified Condition T28-40 (GND) - Body ground Always Below 1 Ω - Measure the voltage of the wire harness side connector.
Standard voltage
Tester Connection Condition Specified Condition T28-1 (IG1) - Body ground Ignition switch ON 10 to 14 V
NG → REPAIR OR REPLACE HARNESS AND CONNECTOR