  1. INSPECT SHIFT SOLENOID VALVE SL 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      Solenoid Connector (SL) - Solenoid Body (SL) 11 to 15 Ω

      If the value is not as specified, replace the shift solenoid valve.

      Fig 1: Measuring Resistance Between Shift Solenoid Valve SL Terminals And Solenoid Body
      G04976575Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Connect the positive (+) lead to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

      OK: 

      The solenoid makes an operating noise. 

      If the operation is not as specified, replace the shift solenoid valve.

      Fig 2: Connecting Positive Lead To Solenoid Valve Terminal 2 And Negative Lead To Terminal 1
      G04976576Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT SHIFT SOLENOID VALVE SLT 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

      OK: 

      The solenoid makes an operating noise. 

      If the operation is not as specified, replace the shift solenoid valve.

      Fig 3: Measuring Resistance Between Shift Solenoid Valve SLT Terminals
      G04963231Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSPECT SHIFT SOLENOID VALVE SLU 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

      OK: 

      The solenoid makes an operating noise. 

      If the operation is not as specified, replace the shift solenoid valve.

      Fig 4: Measuring Resistance Between Shift Solenoid Valve SLU Terminals
      G04963237Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  4. INSPECT SHIFT SOLENOID VALVE SL2 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

      OK: 

      The solenoid makes an operating noise. 

      If the operation is not as specified, replace the shift solenoid valve.

      Fig 5: Measuring Resistance Between Shift Solenoid Valve SL2 Terminals
      G04963200Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  5. INSPECT SHIFT SOLENOID VALVE SL1 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

      OK: 

      The solenoid makes an operating noise. 

      If the operation is not as specified, replace the shift solenoid valve.

      Fig 6: Measuring Resistance Between Shift Solenoid Valve SL1 Terminals
      G04963194Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  6. INSPECT SHIFT SOLENOID VALVE SL3 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

      OK: 

      The solenoid makes an operating noise. 

      If the operation is not as specified, replace the shift solenoid valve.

      Fig 7: Measuring Resistance Between Shift Solenoid Valve SL3 Terminals
      G04975889Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  7. INSPECT SHIFT SOLENOID VALVE SL4 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω

      If the value is not as specified, replace the shift solenoid valve.

    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the shift solenoid valve.

      OK: 

      The solenoid makes an operating noise. 

      If the operation is not as specified, replace the shift solenoid valve.