DTC P0230: Fuel Pump Primary Circuit: Procedure
- CHECK ECM (FPR VOLTAGE)
- Measure the voltage of the ECM connectors.
Standard voltage
Tester Connection Condition Specified Condition E6-15 (FPR) - E3-7 (E1) STA signal ON 11 to 14 V E6-15 (FPR) - E3-7 (E1) STA signal OFF 0 to 3 V
NG → REPLACE ECM
OK: Go to next step
- Measure the voltage of the ECM connectors.
- INSPECT FUEL PUMP RELAY (Marking: F/PMP)
- Remove the fuel pump relay from the engine room No. 2 relay block.
- Measure the resistance of the fuel pump relay.
Standard resistance
Tester Connection Specified Condition 3 - 4 Below 1 Ω 3 - 4 10 kΩ or higher
(when battery voltage is applied to terminals 1 and 2)
NG → REPLACE FUEL PUMP RELAY
OK: Go to next step
- CHECK WIRE HARNESS (FUEL PUMP RELAY (Marking: F/PMP) - ECM)
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Remove the fuel pump relay from the engine room No. 2 relay block.
- Disconnect the E6 ECM connector.
- Measure the resistance of the wire harness side connectors.
Standard resistance
Tester Connection Specified Condition Relay block fuel pump relay terminal 1 - E6-15 (FPR) Below 1 Ω Relay block fuel pump relay terminal 1 or E6-15 (FPR) - Body Ground 10 kΩ or higher
NG → REPAIR OR REPLACE HARNESS AND CONNECTOR
OK → REPLACE ECM