ECM Communication Stop Mode: Procedure
- INSPECT EFI RELAY (Marking: EFI)
- Remove the EFI relay from the engine room No. 2 relay block.
- Measure the resistance of the relay.
Standard resistance
Tester Condition Specified Condition 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
NG → REPLACE EFI RELAY
OK: Go to next step
- CHECK WIRE HARNESS (EFI RELAY - ECM, BATTERY AND BODY GROUND)
- Remove the EFI relay from the engine room No. 2 relay block.
- Disconnect the E4 and E6 ECM connectors.
- Measure the voltage of the wire harness side connector.
Standard voltage
Tester Connection Specified Condition EFI relay terminal 5 - Body ground 10 to 14 V - Measure the resistance of the wire harness side connectors.
Standard resistance
Tester Connection Specified Condition EFI relay terminal 2 - E6-13 (MREL) Below 1 Ω EFI relay terminal 1 - Body ground Below 1 Ω EFI relay terminal 3 - E6-6 (+B) Below 1 Ω EFI relay terminal 3 - E6-5 (+B1) Below 1 Ω E4-2 (E01) - Body ground Below 1 Ω
NG → REPAIR OR REPLACE HARNESS AND CONNECTOR
OK → REPLACE ECM