Freeze Frame Data
WARNING: This page is about a different car, the 2008 Lexus LS 600hL. However, it is still accessible from the selected car via links, so may be relevant.
- FREEZE FRAME DATA
- Connect the Intelligent tester or Techstream to the DLC3
- Turn the power switch ON (IG) and check the freeze frame data by following the prompts on the tester screen.
- Intelligent tester
TILT & TELESCO:
DIAGNOSTIC NOTETester Display Measurement Item/Range Normal Condition TILT POS Current tilt position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)TELSC POS Current telescopic position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)TILT RETURN POS Memorized tilt return position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)TELSC RETRN POS Memorized telescopic return position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)UP LIMIT Uppermost tilt position / NOT MEM or MEM NOT MEM Position is not memorized
MEM Position is memorizedUP LIMIT POS Uppermost tilt position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)DOWN LIMIT Lowermost tilt position / Not Mem or Mem NOT MEM Position is not memorized
MEM Position is memorizedDOWN LIMIT POS Lowermost tilt position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)SHORT LIMIT Shortest telescopic position / Not Mem or Mem NOT MEM Position is not memorized
MEM Position is memorizedSHORT LIMIT POS Shortest telescopic position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)LONG LIMIT Longest telescopic position / Not Mem or Mem NOT MEM Position is not memorized
MEM Position is memorizedLONG LIMIT POS Longest telescopic position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)UP SW (CAN) Input state of tilt up by manual switch / ON or OFF ON Tilt up is activated by manual switch
OFF Tilt up is not activated by manual switchDOWN SW (CAN) Input state of tilt down by manual switch /ON or OFF ON Tilt down is activated by manual switch
OFF Tilt down is not activated by manual switchSHORT SW (CAN) Input state of telescopic short by manual switch / ON or OFF ON Telescopic short is activated by manual switch
OFF Telescopic short is not activated by manual switchLONG SW (CAN) Input state of telescopic long by manual switch / ON or OFF ON Telescopic long is activated by manual switch
OFF Telescopic long is not activated by manual switchT&T MEM 1 Tilt & telescopic memory position 1 / Not Mem or Mem NOT MEM Position is not memorized
MEM Position is memorizedT&T MEM 2 Tilt & telescopic memory position 2 / Not Mem or Mem NOT MEM Position is not memorized
MEM Position is memorizedT&T MEM 3 Tilt & telescopic memory position 3 / Not Mem or Mem NOT MEM Position is not memorized
MEM Position is memorizedT&T AUTOAWAY Auto away and return function / ON or OFF ON Auto away and return function is allowed
OFF Auto away and return function is prohibitedPOWER VOLTAGE Voltage data of power supply / min 0 V, max 20 V Actual power supply voltage 11 to 14 V FREEZ SPD INFO Vehicle speed data / min 0 km/h (0 mph), max 255 km/h (158 mph) Actual vehicle speed IG SW (CAN) Communication state of power switch / ON or OFF ON Communication is normal
OFF Communication is interruptedKEY CODE (CAN) Communication state of key code confirmation signal / ON or OFF ON Communication is normal
OFF Communication is interrupted# CODES Number of diagnosis codes / min 0, wax 255 Actual number of diagnosis codes - Techstream
Tilt & Telescopic:
DIAGNOSTIC NOTETester Display Measurement Item/Range Normal Condition Tilt Position Current tilt position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Telesco Position Current telescopic position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Tilt Return Position Memorized tilt return position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Telesco Return Position Memorized telescopic return position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Tilt Up Limit Uppermost tilt position / Not Mem or Mem Not Mem Position is not memorized
Mem Position is memorizedTilt Up Limit Position Uppermost tilt position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Tilt Down Limit Lowermost tilt position / Not Mem or Mem Not Mem Position is not memorized
Mem Position is memorizedTilt Down Limit Position Lowermost tilt position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Telesco Short Limit Shortest telescopic position / Not Mem or Mem Not Mem Position is not memorized
Mem Position is memorizedTelesco Short Limit Pos Shortest telescopic position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Telesco Long Limit Longest telescopic position / Not Mem or Mem Not Mem Position is not memorized
Mem Position is memorizedTelesco Long Limit Pos Longest telescopic position data / min 0000 H (0 edge), max FFFF H (65535 edge) 7000 to 9000 H
(28672 to 36864 edges)Tilt Up SW (CAN) Input state of tilt up by manual switch / ON or OFF ON Tilt up is activated by manual switch
OFF Tilt up is not activated by manual switchTilt Down SW (CAN) Input state of tilt down by manual switch / ON or OFF ON Tilt down is activated by manual switch
OFF Tilt down is not activated by manual switchTelesco Short SW (CAN) Input state of telescopic short by manual switch / ON or OFF ON Telescopic short is activated by manual switch
OFF Telescopic short is not activated by manual switchTelesco Long SW (CAN) Input state of telescopic long by manual switch / ON or OFF ON Telescopic long is activated by manual switch
OFF Telescopic long is not activated by manual switchS/B Mem 1 Tilt & telescopic memory position 1 / Not Mem or Mem Not Mem Position is not memonzed
Mem Position is memorizedS/B Mem 2 Tilt & telescopic memory position 2 / Not Mem or Mem Not Mem Position is not memonzed
Mem Position is memonzedS/B Mem 3 Tilt & telescopic memory position 3 / Not Mem or Mem Not Mem Position is not memonzed
Mem Position is memonzedT&T Autoaway Function Auto away and return function / ON or OFF ON Auto away and return function is allowed
OFF Auto away and return function is prohibitedPower Source Voltage Voltage data of power supply / min 0 V, max 20 V Actual power supply voltage 11 to 14 V Freeze Speed Info Vehicle speed data / min 0 km/h (0 mph), max. 255 km/h (158 mph) Actual vehicle speed IG SW (CAN) Communication state of power switch / ON or OFF ON Communication is normal
OFF Communication is interruptedKey Code Confirm (CAN) Communication state of key code confirmation signal / ON or OFF ON Communication is normal
OFF Communication is interruptedThe Number of DTCs Number of diagnosis codes / min 0, max 255 Actual number of diagnosis codes
- Intelligent tester