Typical Enabling Conditions
TYPICAL ENABLING CONDITIONS - P0715
| The monitor will run whenever the following DTCs are not present | None |
| Battery voltage | 8 V or more |
| Engine switch | On (IG) |
| Starter | OFF |
TYPICAL ENABLING CONDITIONS - P0717
| The monitor will run whenever the following DTCs are not present | P0746, P0748 (Shift solenoid valve SL1 circuit) P0776, P0778 (Shift solenoid valve SL2 circuit) P0796, P0798 (Shift solenoid valve SL3 circuit) P2808, P2810 (Shift solenoid valve SL4 circuit) P2817, P2819 (Shift solenoid valve SL5 circuit) |
| Battery voltage | 8 V or more |
| Engine switch | On (IG) |
| Starter | OFF |
| Shift change is completed (TCM selected gear before shift change) |
2nd, 3rd, 4th, 5th, 6th, 7th or 8th |
| Output shaft RPM | 1000 RPM or more |
| Park/neutral position switch | OFF |
| Transmission range | Not R position |
| Engine | Running |
| Transmission range switch circuit | Not malfunction |