Integration Control and Panel Assembly Power Source Circuit: Procedure
- INSPECT INTEGRATION CONTROL & PANEL ASSEMBLY
- Disconnect the integration control & panel assembly connector J54.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester connection Condition Specified condition E - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below.
Standard voltage
Tester connection Condition Specified condition B - E Always 10 to 14 V ACC - E Engine SW on (ACC) 10 to 14 V IG+ - E Engine SW on (IG) 10 to 14 V
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE