Entry Functions do not Operate at All: Procedure
- CHECK KEY CANCEL FUNCTION
- Check that the key cancel function is set.
OK
Key cancel function is set.
OK → END (UNSET KEY CANCEL FUNCTION)
NG: Go to next step
- Check that the key cancel function is set.
- INSPECT FUSE (SECURITY, ECU-IG RH)
- Remove the SECURITY and ECU-IG RH fuses from the main body ECU RH.
- Measure the resistance of the fuse.
Standard resistance
Below 1 Ω
NG → REPLACE FUSE
OK: Go to next step
- CHECK WIRE HARNESS (CERTIFICATION ECU - BATTERY AND BODY GROUND)
- Disconnect the U28 ECU connector.
- Measure the voltage and resistance of the wire harness side connector.
Standard voltage
Standard resistance
Tester Connection Condition Specified Condition U28-18 (IG) - Body ground Power switch OFF Below 1 V U28-18 (IG) - Body ground Power switch ON (IG) 10 to 14 V U28-1 (+B1) - Body ground Always 10 to 14 V Tester Connection Specified Condition U28-17 (E) - Body ground Below 1 Ω
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR