Engine Control (SFI) System (Diagnostic (Codes P0010-P043E))
>>
SFI System
>>
DTC P0116: Engine Coolant Temperature Circuit Range / Performance Problem
>>
Typical Malfunction Thresholds
Typical Malfunction Thresholds
ECT SENSOR COLD START MONITOR:
ECT sensor value change
Less than 5°C (41°F)
ECT SENSOR SOAK MONITOR:
Difference between current ECT sensor value and previous ECT sensor value when engine stopped