  1. INSPECT DOOR CONTROL SWITCH (PASSENGER SIDE) 
    1. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Condition Specified Condition
      2 - 3 Lock Below 1 Ω
      2 - 3
      1-2
      OFF (Free) 10 kΩ or higher
      1 - 2 Unlock Below 1 Ω
      Fig 1: Inspecting Door Control Switch (Passenger Side)
      G05863416Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      HINT:

      If the result is not as specified, replace the switch.

    2. Apply battery voltage to the door control switch and check that the switch illuminates.

      OK 

      MEASUREMENT SPECIFIED CONDITION CHART

      Measurement Condition Specified Condition
      Battery positive (+) → Terminal 4
      Battery negative (-) → Terminal 2
      Illuminates

      HINT:

      If the result is not as specified, replace the switch.

      Fig 2: Identifying Switch Illuminating