Park / Neutral Position Switch: Installation
- INSTALL PARK/NEUTRAL POSITION SWITCH ASSEMBLY
- Install the park/neutral position switch to the manual valve shaft.
- Temporarily install the 2 bolts.
- Place a new lock plate and tighten the nut.
Torque: 6.9 N*m (70 kgf*cm, 61 in.*lbf)
- Temporarily install the control shaft lever.
- Turn the lever counterclockwise until it stops and then turn it clockwise 2 notches.
- Remove the control shaft lever.
- Align the groove with the neutral basic line.
- Hold the switch in position and tighten the 2 bolts.
Torque: 5.4 N*m (55 kgf*cm, 48 in.*lbf)
- Using a screwdriver, bend the tabs of the lock plate.
- Install the control shaft lever, washer and the nut.
Torque: 13 N*m(130 kgf*cm, 9 ft.*lbf)
- Connect the park/neutral position switch connector.
- CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
- Connect the control cable to the control shaft lever with the nut.
Torque: 15 N*m (153 kgf*cm, 11 ft.*lbf)
- Install the control cable to the bracket with a new clip.
- Connect the control cable to the control shaft lever with the nut.
- ADJUST PARK/NEUTRAL POSITION SWITCH ASSEMBLY (See ADJUSTMENT )
- INSPECT PARK/NEUTRAL POSITION SWITCH ASSEMBLY OPERATION (See INSPECTION )
- INSPECT SHIFT LEVER POSITION (See ADJUSTMENT )
- ADJUST SHIFT LEVER POSITION (See ADJUSTMENT )
- INSTALL AIR CLEANER BRACKET (See INSTALLATION )
- INSTALL INTAKE AIR RESONATOR SUB-ASSEMBLY (See INSTALLATION )
- INSTALL NO. 1 AIR CLEANER INLET (See INSTALLATION )
- INSTALL AIR CLEANER CASE SUB-ASSEMBLY (See INSTALLATION )
- INSTALL AIR CLEANER CAP SUB-ASSEMBLY (See INSTALLATION )
- INSTALL NO. 2 AIR CLEANER INLET (See INSTALLATION )
- INSTALL BATTERY (See INSTALLATION )
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
HINT:
Some systems need initialization after reconnecting the cable to the negative battery terminal (See INITIALIZATION ).