Inspection Procedure
- CHECK POWER DOOR LOCK OPERATION
- When the master switch assembly door control switch is operated, check that the locked doors unlock.
OK: Door locks operate normally.
NG: GO TO POWER DOOR LOCK CONTROL SYSTEM (See PROBLEM SYMPTOMS TABLE )
OK: Go to next step
- When the master switch assembly door control switch is operated, check that the locked doors unlock.
- READ VALUE USING TECHSTREAM (LOCK SWITCH)
- Using the Techstream, read the Data List.
Smart Access
DIAGNOSTIC NOTE NORMAL CONDITION CHARTTester Display Measurement Item/Range Normal Condition Diagnostic Note Pr-Door Trigger Switch Passenger side rear door outside handle lock switch / ON or OFF ON: Entry lock switch pushed
OFF: Entry lock switch not pushed- OK: On Techstream screen, item changes between ON and OFF according to above chart.
NG: Go to step 3
OK: REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (See REMOVAL )
- Using the Techstream, read the Data List.
- CHECK HARNESS AND CONNECTOR (REAR DOOR OUTSIDE HANDLE - DOOR ELECTRICAL KEY OSCILLATOR)
- Disconnect the z26 oscillator connector.
- Disconnect the z25 handle connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition z26-9 (TRG-) - z25-1 (TRG-) Always Below 1 Ω z26-9 (TRG-) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (CERTIFICATION ECU [SMART KEY ECU ASSEMBLY] - REAR DOOR OUTSIDE HANDLE)
- Disconnect the E30 ECU connector.
- Disconnect the z25 handle connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition E30-26 (TSW4) - z25-3 (TRG+) Always Below 1 Ω E30-26 (TSW4) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- INSPECT REAR DOOR OUTSIDE HANDLE RH
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition z25-1 (TRG-) - z25-3 (TRG+) Lock switch not pushed 10 kΩ or higher Lock switch pushed Below 1 Ω
NG: REPLACE REAR DOOR OUTSIDE HANDLE (See DISASSEMBLY )
OK: Go to next step
- Measure the resistance according to the value(s) in the table below.
- REPLACE DOOR ELECTRICAL KEY OSCILLATOR
- Replace the door electrical key oscillator (See DISASSEMBLY ).
- CHECK DOOR ELECTRICAL KEY OSCILLATOR OPERATION
- Check that the entry function operates normally.
OK: Operates normally.
NG: REPLACE CERTIFICATION ECU (SMART KEY ECU ASSEMBLY) (See REMOVAL )
OK: END (DOOR ELECTRICAL OSCILLATOR IS DEFECTIVE)
- Check that the entry function operates normally.