Smog Ventilation Sensor: Inspection
- INSPECT SMOG VENTILATION SENSOR
- HC, CO:
- Apply battery voltage between terminals 3 (IG) and 6 (E).
- Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor, and measure the resistance between terminals 1 (SG) and 2 (DGS)
OK: When the sensor is exposed to the exhaust gas, the resistance decreases.
HINT:
The resistance before blowing exhaust gas is 10 to 40 kΩ.
If the resistance is not as specified, replace the smog ventilation sensor.
- NOx:
- Apply battery voltage between terminals 3 (IG) and 6(E)
- Allow exhaust gas (NOx) to travel to the sensing portion of the smog ventilation sensor, and measure the resistance between terminals 1 (SG) and 4 (DGS1).
OK: When the sensor is exposed to the exhaust gas, the resistance increases.
HINT:
The resistance before blowing exhaust gas is 10 to 40 kΩ.
If the resistance is not as specified, replace the smog ventilation sensor.
- HC, CO: