Inspection Procedure
- CHECK HARNESS AND CONNECTOR (INFRARED RAY SENSOR - AIR CONDITIONING AMPLIFIER)
- Disconnect the X13 infrared ray sensor connector
- Disconnect the L76 air conditioning amplifier connector
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTOR SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition X13-3 (LIN1) - L76-28 (LIN1) Always Below 1 Ω X13-3 (LIN1) - Body ground Always 10 kΩ or higher L76-28 (LIN1) - Body ground
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- REPLACE INFRARED RAY SENSOR
- Replace the infrared ray sensor with a normal one (see REMOVAL )
- RECHECK DTC
- Clear the DTCs (see DTC CHECK / CLEAR ).
- Check for DTCs (see DTC CHECK / CLEAR
)
OK: DTC B1492 is not output.
NG: REPLACE AIR CONDITIONING AMPLIFIER (See REMOVAL )
OK: END (INFRARED RAY SENSOR IS DEFECTIVE)