Inspection Procedure
- READ VALUE OF DATA LIST (STARTER SIGNAL)
- Connect the Techstream to the DLC3.
- Turn the engine switch on (IG).
- Turn the Techstream on.
- Enter the following menus: Powertrain / ECT / Data List.
- Read the value displayed on the Techstream.
- Crank the engine.
- Read the value displayed on the Techstream.
OK
STANDARD CONDITION CHARTTester Display Condition Standard Starter Signal Engine switch on (IG) OFF Starter Signal Engine Is cranking ON
NG: Go to step 4
OK: Go to Next Step
- CHECK TCM (STA VOLTAGE)
- Disconnect the A12 and E5 TCM connectors.
- Measure the voltage of the wire harness side connectors.
Standard Voltage
VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition A12-3 (STA) - E5-7 (E1) Always Below 2 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (TCM - ST RELAY)
OK: Go to Next Step
- REPLACE TCM
- Replace the TCM (see REMOVAL ).
NEXT: PERFORM A/T CODE REGISTRATION (See REGISTRATION )
- INSPECT PARK/NEUTRAL POSITION SWITCH
- Disconnect the E49 park/neutral position switch connector.
- Measure the resistance of the park/neutral position switch when the shift lever is moved to each position.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition 4 (B) - 5 (L) Shift lever on P Below 1 Ω 4 (B) - 5 (L) Shift lever on N Below 1 Ω
NG: REPLACE PARK/NEUTRAL POSITION SWITCH (See REMOVAL )
OK: CHECK CRANKING HOLDING FUNCTION CIRCUIT (See CRANKING HOLDING FUNCTION CIRCUIT )