Purge Valve: Inspection
- INSPECT VACUUM SWITCHING VALVE ASSEMBLY
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 23 to 26 Ω 1 - Body ground Always 10 kΩ or higher 2 - Body ground Always 10 kΩ or higher If the result is not as specified, replace the vacuum switching valve assembly.
- Check operation of the vacuum switching valve assembly.
- Check that air does not flow from port E to port F
- Apply battery voltage across terminals 1 and 2.
- Check that air flows from port E to port F. If the result is not as specified, replace the vacuum switching valve assembly
- Measure the resistance according to the value(s) in the table below.