Inspection Procedure
- INSPECT COMBINATION METER
- Disconnect the J34 connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J34-1 (E2) - Body ground Always Below 1 Ω J34-13 (ES) - Body ground Always Below 1 Ω - Measure the voltage according to the value(s) in the table below
Standard Voltage
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J34-12 (IG+) - Body ground Engine switch on (IG) 11 to 14V J34-23 (B) - Body ground Always 11 to 14 V J34-24 (B) - Body ground Always 11 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE COMBINATION METER (See REMOVAL )