Inspection Procedure
- CHECK HARNESS AND CONNECTOR (TERMINAL TC of DLC3 - ECM)
- Disconnect the A6 connector from the ECM.
- Measure the resistance according to the value (s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition A6-21 (TC) - J21-13 (TC) Always Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (DLC3 - ECM)
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (TERMINAL CG of DLC3 - BODY GROUND)
- Measure the resistance according to the value (s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J21-4 (CG) - Body ground Always Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR (DLC3 - BODY GROUND)
OK: Go to next step
- Measure the resistance according to the value (s) in the table below
- CHECK HARNESS AND CONNECTOR (TERMINAL TC of DLC3 - BODY GROUND)
- Measure the resistance according to the value (s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition J21-13 (TC) - Body ground Always 10 kΩ or higher
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR OR EACH ECU
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (See PROBLEM SYMPTOMS TABLE )
- Measure the resistance according to the value (s) in the table below.