LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2008 >> IS F >> Repair and Diagnosis (Single Page) >> Steering >> Steering Column >> Steering Column >> Power Tilt And Power Telescopic Steering Column System >> Data List / Active Test

Data List / Active Test

  1. DATA LIST 

    HINT

    Using the Techstream to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time

    NOTE: In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
    1. Turn the engine switch off
    2. Connect the Techstream to the DLC3.
    3. Turn the engine switch on (IG)
    4. Turn the Techstream on
    5. Enter the following menus' Chassis / Tilt & Telescopic / Data List
    6. According to the display on the Techstream, read the Data List.

      Tilt & Telescopic 

      DATA LIST

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      T&T Autoaway Function Auto away and return function/ OFF or ON OFF Auto away and return function is restrained
      ON Auto away and return function is allowed
      -
      Tilt Position Current tilt position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Telesco Position Current telescopic position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Tilt Return Position Memorized tilt return position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Telesco Return Position Memorized telescopic return position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      T&T Mem1 Tilt & telescopic memory position 1/Not Mem or Mem Not Mem Position is not memorized
      Mem Position is memorized
      -
      Tilt Memory Pos 1 Tilt data of memory position 1/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Telesco Memory Pos 1 Telescopic data of memory position 1/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      T&T Mem2 Tilt & telescopic memory position 2/Not Mem or Mem Not Mem Position is not memorized
      Mem Position is memorized
      -
      Tilt Memory Pos 2 Tilt data of memory position 2/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Telesco Memory Pos 2 Telescopic data of memory position 2/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      T&T Mem3 Tilt & telescopic memory position 3/Not Mem or Mem Not Mem Position is not memorized
      Mem Position is memorized
      -
      Tilt Memory Pos 3 Tilt data of memory position 3/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Telesco Memory Pos 3 Telescopic data of memory position 3/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Tilt Up Limit Uppermost tilt position/Not Mem or Mem Not Mem Position is not memorized
      Mem Position is memorized
      -
      Tilt Up Limit Position Uppermost tilt position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Tilt Down Limit Pos Lowermost tilt position/Not Mem or Mem Not Mem Position is not memorized
      Mem Position is memorized
      -
      Tilt Down Limit Position Lowermost tilt position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Telesco Short Limit Pos Shortest telescopic position/ Not Mem or Mem Not Mem Position is not memorized
      Mem Position is memorized
      -
      Telesco Short Limit Pos Shortest telescopic position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Telesco Long Limit Longest telescopic position/ Not Mem or Mem Not Mem Position is not memorized
      Mem Position is memorized
      -
      Telesco Long Limit Pos Longest telescopic position data/Min 0
      Max 65535
      7000 to 9000 H (28672 to 36864 edge) -
      Up Switch Input state of tilt up by manual switch/OFF or ON OFF Tilt up is not activated by manual switch
      ON Tilt up is activated by manual switch
      -
      Tilt Up SW (MPX) Communication state of tilt up input by manual switch/OFF or ON OFF Tilt up is not activated by manual switch
      ON Tilt up is activated by manual switch
      -
      Down Switch Input state of tilt down by manual switch/OFF or ON OFF Tilt down is not activated by manual switch
      ON Tilt down is activated by manual switch
      -
      Tilt Down SW (MPX) Communication state of tilt down input by manual switch/OFF or ON OFF Tilt down is not activated by manual switch
      ON Tilt down is activated by manual switch
      -
      Telesco Short Switch Input state of telescopic short by manual switch/OFF or ON OFF Telescopic short is not activated by manual switch
      ON Telescopic short is activated by manual switch
      -
      Telesco Short SW (MPX) Communication state of telescopic short input by manual switch/OFF or ON OFF Telescopic short is not activated by manual switch
      ON Telescopic short is activated by manual switch
      -
      Telesco Long Switch Input state of telescopic long by manual switch/OFF or ON OFF Telescopic long is not activated by manual switch
      ON Telescopic long is activated by manual switch
      -
      Telesco Long SW (MPX) Communication state of telescopic long input by manual switch/OFF or ON OFF Telescopic long is not activated by manual switch
      ON Telescopic long is activated by manual switch
      -
      T&T Manual SW Data Voltage data of manual switch/Min 0 V
      Max 5 V
      Neutral position Below 0 2V
      Tilt up 167 to 2 13 V
      Tilt down 0 54 to 0 74 V
      Telescopic contract 1 08 to 1 40 V
      Telescopic extend 2 22 to 2 77 V
      -
      Power Source Voltage Voltage data of power supply/Min 0 V
      Max 20 V
      Actual power supply voltage 11 to 14 V -
      Freeze Speed Info Vehicle speed data/0 Km
      Max 255 Km
      Actual vehicle speed -
      IG Switch (MPX) Communication state of engine switch/OFF or ON OFF Communication is interrupted
      ON Communication is normal
      -
      IG Switch Input state of engine switch/OFF or ON OFF Input signal is interrupted
      ON Input signal is normal
      -
      Key Switch/MPX Communication state of key switch confirmation signal/ OFF or ON OFF Communication is interrupted
      ON Communication is normal
      -
      Key Code Confirm (MPX) Communication state of key code confirmation signal/ OFF or ON OFF Communication is interrupted
      ON Communication is normal
      -
      Receive from Meter Communication state of combination meter signal/OK or Interpt OK Communication is normal Interpt Communication is interrupted -
      Receive from Body Communication state of body ECU signal/OK or Interpt OK Communication is normal Interpt Communication is interrupted -
      Receive from Seat ECU Communication state of seat ECU signal/OK or Interpt OK Communication is normal Interpt Communication is interrupted -
      Receive from Combi Communication state of combination switch ECU signal/ OK or Interpt OK Communication is normal Interpt Communication is interrupted -
      Power ECU Info Communication state of power source control ECU signal/OK or Interpt OK Communication is normal Interpt Communication is interrupted -
      The Number of DTCs Number of diagnosis code/Min 0
      Max 255
      Actual number of diagnosis code -
    7. Enter the following menus. Body Electrical / Combination Switch / Data List
    8. According to the display on the Techstream, read the Data List.

      Combination Switch 

      DATA LIST

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Tilt Up SW Tilt UP switch/ON or OFF ON Tilt up is activated by manual switch
      OFF Tilt up is not activated by manual switch
      -
      Tilt Down SW Tilt DOWN switch/ON or OFF ON Tilt down is activated by manual switch
      OFF Tilt down is not activated by manual switch
      -
      Telesc Long SW Telesco LONG switch status/ON or OFF ON Telescopic long is activated by manual switch
      OFF Telescopic long is not activated by manual switch
      -
      Telesc Short SW Telesco SHORT switch status/ON or OFF ON Telescopic short is activated by manual switch
      OFF Telescopic short is not activated by manual switch
      -
  2. ACTIVE TEST 

    HINT:

    Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed Performing Active Tests early in troubleshooting is one way to save diagnostic time Data List information can be displayed while performing Active Tests.

    1. Turn the engine switch off.
    2. Connect the Techstream to the DLC3.
    3. Turn the engine switch on (IG)
    4. Turn the Techstream on.
    5. Enter the following menus- Chassis / Tilt&Telescopic / Active Test.
    6. According to the display on the Techstream, perform the Active Test.

      Tilt & Telescopic 

      ACTIVE TEST DETAIL

      Tester Display Test Part Control Range Diagnostic Note
      Tilt Tilt operation DOWN OFF or DOWN
      UP OFF or UP
      Telesco Telescopic operation LONG OFF or LONG
      SHORT OFF or SHORT