LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2008 >> GS 460 >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Door Lock >> Smart Access System With Push-Button Start >> Entry Functions do not Operate at All >> Inspection Procedure

Inspection Procedure

  1. CHECK KEY CANCEL FUNCTION 
    1. Check that the key cancel function is set.

      OK: Key cancel function is set. 

    OK : END (UNSET KEY CANCEL FUNCTION) 

    NG : Go to next step 

  2. CHECK WIRE HARNESS (CERTIFICATION ECU ASSEMBLY - BATTERY AND BODY GROUND) 
    1. Disconnect the U28 ECU connector.
    2. Measure the voltage and resistance of the wire harness side connector.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Condition Specified Condition
      U28-18 (IG) - Body ground Engine switch off Below 1 V
      U28-18 (16) - Body ground Engine switch on (IG) 10 to 14 V
      U28-1 (+B1) - Body ground Always 10 to 14 V

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION CHART

      Tester Connection Condition Specified Condition
      U28-17 (E) - Body ground Always Below 1 Ω
      Fig 1: Identifying Terminals Of U28 ECU Connector
      G05299285Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG : REPAIR OR REPLACE HARNESS AND CONNECTOR 

    OK : REPLACE CERTIFICATION ECU ASSEMBLY