Typical Malfunction Thresholds
TYPICAL MALFUNCTION THRESHOLDS
| Either of the following conditions 1 or 2 is met: | - |
| 1. Frequency that both of the following conditions (a) and (b) are met: | 5 time or more |
| (a) Engine RPM - target engine RPM | Less than -100 rpm, or more than 200 rpm |
| (b) Vehicle condition | Stop after vehicle was driven by 7 mph (11.2 km/h) or more |
| 2. Frequency that both of the following conditions (c) and (d) are met: | Once |
| (c) Engine RPM - target engine RPM | Less than -100 rpm, or more than 200 rpm |
| (d) ISC flow rate learning value | 1.3 L/sec. or less, or 10.3 L/sec. or more |