Inspection Procedure

  1. CHECK KEY CANCEL FUNCTION 
    1. Check that the key cancel function is set.

      OK: Key cancel function is set. 

    OK: END (UNSET KEY CANCEL FUNCTION) 

    NG: Go to next step 

  2. INSPECT FUSE (SECURITY, ECU-IG RH) 
    1. Remove the SECURITY and ECU-IG RH fuses from the main body ECU RH.
    2. Measure the resistance of the fuse.

      Standard resistance: Below 1 Ω 

    NG: REPLACE FUSE 

    OK: Go to next step 

  3. CHECK WIRE HARNESS (CERTIFICATION ECU - BATTERY AND BODY GROUND) 
    1. Disconnect the U28 ECU connector.
    2. Measure the voltage and resistance of the wire harness side connector.

      Standard voltage 

      VOLTAGE SPECIFIED CONDITIONS

      Tester Connection Condition Specified Condition
      U28-18 (IG) - Body ground Power switch OFF Below 1 V
      U28-18 (IG) - Body ground Power switch ON (16) 10 to 14 V
      U28-1 (+B1) - Body ground Always 10 to 14 V

      Standard resistance 

      RESISTANCE SPECIFIED CONDITIONS

      Tester Connection Specified Condition
      U28-17 (E) - Body ground Below 1 Ω
      Fig 1: Identifying U28 ECU Connector Terminals
      G05819421Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

    NG: REPAIR OR REPLACE HARNESS OR CONNECTOR 

    OK: REPLACE CERTIFICATION ECU