Ultrasonic Sensor: Inspection
- INSPECT NO. 1 ULTRASONIC SENSOR
- Measure the resistance of the sensor.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition 1 (E) - 2 (S) Always 600 to 1,200 kΩ Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NOTE: Set the tester to the 100 kΩ range before performing the measurement.If the result is not as specified, replace the ultrasonic sensor.
- Measure the resistance of the sensor.
- INSPECT NO. 2 ULTRASONIC SENSOR
- Measure the resistance of the sensor.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition 1 (E) - 2 (S) Always 600 to 1,200 kΩ Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NOTE: Set the tester to the 100 kΩ range before performing the measurement.If the result is not as specified, replace the ultrasonic sensor.
- Measure the resistance of the sensor.
- INSPECT NO. 3 ULTRASONIC SENSOR
- Measure the resistance of the sensor.
Standard resistance:
TESTER CONNECTION SPECIFIED CONDITIONTester Connection [Tester (+) - Tester (-)] Condition Specified Condition 3 (S) - 2 (E) Always 30 to 50 kΩ 2 (E) - 3 (S) Always 30 to 50 kΩ 1 (T) - 2 (E)* Always 230 to 430 kΩ 2 (E) - 1 (T)* Always 1 MΩ or higher NOTE:- Set the tester to the 100 kΩ range before performing the measurement.
- *: Measurement values may vary depending on the tester used. If results seem inaccurate, reverse the polarity (+-) and measure again.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
If the result is not as specified, replace the ultrasonic sensor.
- Measure the resistance of the sensor.