Inspection Procedure
- INSPECT FUSE (LH-IG)
- Remove the LH-IG fuse from the main body ECU LH.
- Measure the resistance of the LH-IG fuse.
Standard resistance: Below 1 Ω
NG: REPLACE FUSE
OK: Go to next step
- CHECK WIRE HARNESS (CLEARANCE WARNING ECU - BATTERY)
- Disconnect the A38 ECU connector.
- Measure the voltage of the wire harness side connector.
Standard voltage
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Condition Specified Condition A38-8 (IG) - Body ground Power switch on (IG) 10 to 14 V
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK WIRE HARNESS (CLEARANCE WARNING ECU - BODY GROUND)
- Disconnect the A38 ECU connector.
- Measure the resistance of the wire harness side connector.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONTester Connection Specified Condition A38-27 (E) - Body ground Below 1 Ω
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE