Monitor Result
Detailed information on Checking Monitor Status (see CHECKING MONITOR STATUS ).
The vest value and test limit information are in the following table. Check the monitor result and test values after performing the monitor drive pattern (refer to "Confirmation Monitor").
- Monitor Identification Data (MID) is assigned to each emissions-related component.
- Test Identification Data (TID) is assigned to each test value.
- Scaling is used to calculate the test value indicated on generic OBD II scan tools.
Catalyst bank 1 - Active A/F control method
TEST VALUE AND TEST LIMIT INFORMATION (CATALYST BANK 1 - ACTIVE A/F CONTROL METHOD)
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $21 | $A9 | Multiply by 0.0003 (no dimension) | Oxygen storage capacity of catalyst | Minimum test limit for catalyst | Maximum test limit for catalyst |
Catalyst bank 2 - Active A/F control method
TEST VALUE AND TEST LIMIT INFORMATION (CATALYST BANK 2 - ACTIVE A/F CONTROL METHOD)
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $22 | $A9 | Multiply by 0.0003 (no dimension) | Oxygen storage capacity of catalyst | Minimum test limit for catalyst | Maximum test limit for catalyst |