Vacuum Switching Valve: Inspection
- INSPECT VACUUM SWITCHING VALVE (PURGE VSV)
- Measure the resistance according to the value(s) in the table below.
Standard resistance
TESTER CONNECTION AND SPECIFIED CONDITIONTester Connection Condition Specified Condition 1-2 20°C (68°F) 23 to 26 Ω 1 - Body ground Always 10 kΩ or higher 2 - Body ground Always 10 kΩ or higher If the result is not as specified, replace the purge VSV.
- Check operation of the purge VSV.
- Check that air does not flow from port E to port F.
- Apply battery voltage across terminals 1 and 2.
- Check that air flows from port E to port F. If the result is not as specified, replace the purge VSV.
- Measure the resistance according to the value(s) in the table below.