Inspection Procedure
- INSPECT FUSE (RR MPX-B 2)
- Disconnect the RR MPX-B 2 fuse from the luggage room junction block.
- Measure the resistance of the fuse.
Standard resistance
TERMINALS RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition RR MPX-B 2 fuse Always Below 1 Ω
NG: REPLACE FUSE
OK: GO TO NEXT STEP
- CHECK HARNESS AND CONNECTOR (REAR POWER SEAT MODULE SWITCH BATTERY AND BODY GROUND)
- Disconnect the S15 or r2 switch connector.
- Measure the resistance of according to the value(s) in the table below.
Standard resistance: w/ Ottoman
TERMINALS RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition S15-5 (E) - Body ground Always Below 1 Ω w/o Ottoman
TERMINALS RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition r2-3 (E) - Body ground Always Below 1 Ω - Measure the voltage of according to the value(s) in the table below.
Standard voltage: w/ Ottoman
TERMINALS VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition S15-6 (B) - Body ground Always 11 to 14 V w/o Ottoman
TERMINALS VOLTAGE SPECIFICATIONTester Connection Condition Specified Condition r2-11 (B) - Body ground Always 11 to 14 V
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (See PROBLEM SYMPTOMS TABLE )