LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2007 >> GS 450h >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning >> Air Conditioning System >> Data List / Active Test

Data List / Active Test

  1. READ DATA LIST 

    HINT:

    Using the intelligent tester's DATA LIST allows switch, sensor, actuator and other item values to be read without removing any parts. Reading the Data List early in troubleshooting is one way to save time.

    1. Connect the intelligent tester (with CAN VIM) to the DLC3.
    2. Turn the power switch ON (IG).
    3. Read the DATA LIST according to the display on the tester.
      Fig 1: Connecting Intelligent Tester To DLC3
      G05306806Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002

      A/C amplifier 

      DATA LIST - A/C AMPLIFIER

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      ROOM TEMP (Room temperature sensor) Room temperature sensor / Min.: -6.5°C (-20.3°F)
      Max.: 57.25°C (135.05°F)
      Actual room temperature is displayed Open in circuit: -6.5°C (-20.3°F)
      Short in circuit: 57.25°C (135.05°F)
      AMBI TEMP SENS (Ambient temperature sensor) Ambient temperature sensor / Min.: -23.3°C (-9.94°F)
      Max.: 65.95°C (150.71°F)
      Actual ambient temperature is displayed Open in circuit: -23.3°C (-9.94°F)
      Short in circuit: 65.95°C (150.71°F)
      EVAP TEMP (Evaporator temperature sensor) Evaporator temperature sensor / Min.:-29.7°C (-21.46°F)
      Max.: 59.55°C (139.19°F)
      Actual evaporator temperature is displayed Open in circuit: -29.7°C (-21.46°F)
      Short in circuit: 59.55°C (139.19°F)
      SOLAR SENS-D (Solar Sensor (D side)) Driver side solar sensor / Min.: 0, Max.: 255 Driver side solar sensor voltage increases as brightness increases Open in circuit: 0
      Short in circuit: 255
      SOLAR SENS-P (Solar Sensor (P side)) Passenger side solar sensor / Min.: 0, Max.: 255 Passenger side solar sensor voltage increases as brightness increases Open in circuit: 0
      Short in circuit: 255
      COOLANT TEMP (Engine coolant temperature) Engine coolant temperature / Min.: 1.3°C (34.34°F)
      Max.: 90.55°C (194.99°F)
      Actual engine coolant temperature is displayed while engine is warmed up -
      SET TEMP-D (Set temperature (D - side)) Driver side set temperature / Min.: 0, Max.: 255 Driver side actual set temperature is displayed -
      SET TEMP-P (Set temperature (P - side)) Passenger side set temperature / Min.: 0, Max.: 255 Passenger side actual set temperature is displayed -
      ESTIMATE TEMP-D (Estimated temperature (D side)) Driver side estimated temperature / Min.: -358.4°C (-613.12°F)
      Max.: 358.4°C (677.12°F)
      Driver side actual estimated temperature is displayed -
      ESTIMATE TEMP-P (Estimated temperature (P side)) Passenger side estimated temperature / Min.: -358.4°C (-613.12°F)
      Max.: 358.4X (677.12°F)
      Passenger side actual estimated temperature is displayed -
      HAND FREE TEL (Handsfree telephone) Handsfree telephone / OFF or ON - -
      BLOWER LEVEL (Blower motor speed level) Blower motor speed level / Min.: 0 level, Max.: 31 level Increases in range between 0 and 31 as blower motor speed increases -
      AMBI TEMP (Adjusted ambient temperature) Adjusted ambient temperature / Min.: -30.8°C (-23.44°F)
      Max.: 50.8°C (123.44°F)
      - -
      EMISS GAS SENS (Emission gas sensor) Emission gas / Min.: 0, Max.: 255 Increases as the gas amount increases -
      SET TEMP SHIFT (Shift set temperature) Shift set temperature / +2 C, +1 C, NORMAL, -1 C, -2 C Customized value will be displayed -
      AIR INLET MODE (Air Inlet mode) Air inlet mode / AUTO, MANUAL Customized value will be displayed -
      COMPRESSOR MODE (Compressor mode) Compressor mode / AUTO, MANUAL Customized value will be displayed -
      COMPRS/ DEF OPER (Compressor/ DEF operation mode) Compressor / DEF mode / LINK, NORMAL Customized value will be displayed -
      GAS SENS SHIFT (Emission Gas Sensor Shift) Emission gas sensor shift / MU MORE, MORE, LI MORE, NORMAL, LI LESS, LESS, MU LESS Customized value will be displayed -
      BUTTON PRS BUZ (Button press buzzer) Button press buzzer / ON, OFF Customized value will be displayed -
      FOOT AIR LEAK (Foot air leak) Foot air leak/ON, OFF Customized value will be displayed -
      AUTO BLOW UP (Foot / DEF automatic blower up function) Foot / DEF auto blower up function / ON, OFF Customized value will be displayed -
      FOOT/DEF MODE (Foot /DEF auto mode) Foot / DEF auto mode / ON, OFF Customized value will be displayed -
      AMBIENT TMP SFT (Ambient temperature Shift) Ambient temperature shift / +3 C, +2 C, +1 C, NORMAL, -1 C, -2 C, -3C Customized value will be displayed -
      DESTINATION (Destination) Destination / DOMEST, USA, EUROPE, AUSTRAL, MIDEAST, NO INFO Changes value with destinations -
      NOX GAS SENS (Emission gas Nox sensor) Emission gas NOx sensor / Min.: 0, Max.: 255 Increases as gas amount increases -
      REG PRESS SENS (Refrigerant pressure sensor) Refrigerant pressure sensor / Min.: 0, Max.: 255 Actual refrigerant pressure is displayed -
      HUMIDITY SENS (Humidity sensor) Humidity sensor / Min.: 0%, Max.: 100% Actual room humidity is displayed -
      AIR MIX PULSE-D (Air mix servo motor target pulse (D side)) Driver side air mix servo motor target pulse / Min.: 0, Max.: 255 Customized value will be displayed -
      AIR MIX PULSE-P (Air mix servo motor target pulse (P side)) Passenger side air mix servo motor target pulse / Min.: 0, Max.: 255 Customized value will be displayed -
      AIR OUT PULSE-D (Air Out Pulse-D) Driver side air outlet servo motor target pulse / Min.: 0, Max.: 255 Customized value will be displayed -
      A/I DAMP PLS (Air inlet damper target pulse) Air inlet damper target pulse / Min.: 0, Max.: 255 Customized value will be displayed -
      A/B DAMP PLS (Cool air bypass pulse) Passenger side cool air bypass pulse / Min.: 0, Max.: 255 Customized value will be displayed -
      COMPRS SPD (Compressor speed) Compressor speed / Min.: 0, Max.: 65,535 RPM Displayed actual rotation speed in range between 0 RPM and 8,600 RPM -
      COMPRS TARG SPD (Compressor target speed) Compressor target speed / Min.: 0, Max.: 65,535 RPM Displayed actual rotation speed in range between 0 RPM and 8,600 RPM -
      #CODES (Number of trouble codes) Number of trouble codes / Min.: 0, Max.: 255 Number of DTCs will be displayed -

      ECM 

      DATA LIST - ECM

      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      A/C SIG (A/C Signal) A/C signal / ON or OFF ON: A/C ON
      OFF: A/C OFF
      -
  2. PERFORM ACTIVE TEST 

    HINT:

    Performing the intelligent tester's ACTIVE TEST allows relay, VSV, actuator and other items to be operated without removing any parts. Performing the ACTIVE TEST early in troubleshooting is one way to save time. The Data List can be displayed in the ACTIVE TEST.

    1. Connect the intelligent tester (with CAN VIM) to the DLC3.
    2. Turn the power switch ON (IG).
    3. Perform the ACTIVE TEST according to the display on the tester.

      A/C amplifier 

      ACTIVE TEST - A/C AMPLIFIER

      Tester Display Test Part Control Range
      BLOWER MOTOR (Blower motor) Blower motor / Min.: Level 0, Max.: Level 31 -
      DEFOGER RLY-R (Defogger Relay (Rear)) Defogger relay (Rear) / OFF, ON -
      AIR MIX PULSE-D (Air mix servo motor pulse (D side)) Driver side air mix servo motor pulse / Min.: 0, Max.: 255 -
      AIR MIX PULSE-P (Air mix servo motor pulse (P side)) Passenger side air mix servo motor pulse / Min.: 0, Max.: 255 -
      AIR OUT PULSE-D (Air outlet servo motor pulse (D side) Driver side air outlet servo motor pulse / Min.: 0, Max.: 255 -
      A/I DAMP PLS (Air inlet damper target pulse) Air inlet damper target pulse / Min.: 0, Max.: 255 -
      A/B DAMP PLS (Cool air bypass pulse) Cool air bypass pulse / Min.: 0, Max.: 255 -
      ELECTRICAL FAN (Electrical fan) Electrical fan / OFF, ON -
      WATER PUMP (Water pump) Water pump / OFF, ON -
      WATER PUMP (Water pump) Activate water pump / OFF, ON -