LEMON Manuals: Even more car manuals for everyone
Home >> Lexus >> 2007 >> GS 450h >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System - DTC P0327 - P1235 >> DTC P0420 Catalyst System Efficiency Below Threshold (Bank 1); DTC P0430 Catalyst System Efficiency Below Threshold (Bank 2) >> Typical Enabling Conditions

Typical Enabling Conditions

TYPICAL ENABLING CONDITIONS

Monitor runs whenever following DTCs are not present P0011 (VVT System 1 - Advance)
P0012 (VVT System 1 - Retard)
P0021 (VVT System 2 - Advance)
P0022 (VVT System 2 - Retard)
P0031, 32, 51, 52 (A/F Sensor heater - Sensor 1)
P0037, 38, 58, 59 (HO2 Sensor heater - Sensor 2)
P0100 - P0103 (MAF meter)
P0115 - P0118 (ECT sensor)
P0120 - P0223, P2135 (TP sensor)
P0125 (Insufficient ECT for Closed Loop)
P0136, P0156 (HO2 Sensor - Sensor 2)
P0171, P0172 (Fuel system)
P0300 - P0306 (Misfire)
P0335 (CKP sensor)
P0340 (VVT sensor)
P0351 - P0356 (Igniter)
P2196, P2198 (A/F Sensor - rationality)
P2A00, P2A03 (A/F Sensor - slow response)
Battery voltage 11 V or more
IAT -10°C (14°F) or more
ECT 75°C (167°F) or more
Atmospheric pressure 570 mmHg or more
Idle OFF
Engine RPM Less than 3,200 rpm
Fuel system status Closed loop
A/F sensor Activated
Engine load 5 to 80%
All of the following conditions 1, 2 and 3 are met: -
1. MAF 3 to 63 g/sec.
2. Front catalyst temperature (estimated) 530 to 820°C (986 to 1,508°F)
3. Rear catalyst temperature (estimated) 380 to 700°C (716 to 1,292°F)
EVAP system monitor The monitor has not run yet or the vacuum introduction has been completed.
A/F sensor monitor Completed
Rear HO2S monitor Completed
Shift position -